TempStick Probe -80
TempStick Probe -80 temperature data logger is a miniaturized temperature recorder with cable and rigid metal probe of verious lengths, calibrated from …
MicroW L Ultra Freeze is a data logger for ultra low temperatures from -80°C to 140°C (calibration from -40°C to 140°C) with 20, 100 mm or on demand length external probe (probes cannot be switched) on a 3 mm base (base height is not counted for probe length), managed with Windows software and USB interface (DiskInterface HS, Multibay). Battery is user replaceable and the data logger is provided with a Reference traceable cetificate on 6 points.
With calibration from -40°C it can be used also at -80°C with an accuracy within ± 0,5 °C within range -80 °C ÷ -40 °C. If -80°C is requested to be on the certificate, an extra calibration point for very low temperatures must be purchased. It is particularly indicated for monitoring and validation of ultra freezers.
Note: if used below -30°C, battery life will be highly reduced. Mission max duration at -80°C: 12 hours. Using the logger for long periods below -40°C will constantly reduce mission max duration. For longer missions purchase the -80°C special battery for S-MicroW L Ultra Freeze. With -80°C special battery mission max duration at -80°C with the special battery: 2 months. Using the logger for long periods below -40°C will constantly reduce mission max duration. Max temperature of use of the -80°C battery is 80°C: REMOVE IT AND USE STANDARD BATTERY TO USE THE LOGGER IN AUTOCLVE OR ABOVE 80°C.
The system is made up by:
Dimensions | 39 h X 20 Ø (mm) |
---|---|
Probe dimensions | Probe base dimensions 3 h X 14 Ø (mm) - Probe 20/100/on demand l X 3 Ø (mm) (l on demand: min. 12 mm / max. 175 mm. For longer probes ask for quotation) |
Weight | 50 g |
Materials | Stainless steel AISI316L, PEEK |
Temperature range | -80 °C ÷ +140 °C |
Standard calibration points (temperature) | -40/-20/0/25/50/75/100/121/140°C |
Extra calibration points (temperature) | Within the range -80 °C ÷ +140 °C |
Temperature resolution | 0,01 °C |
Temperature accuracy | ± 0,1 °C (within the calibration range) / ± 0,5 °C (- 80 °C ÷ -40°C without -80°C point) |
Memory (n. of acquisitions) | 20.224 |
Acquisition step | From 1 every second up, with 1 second steps |
Protection degree | IP68 |
Battery life | +10.000.000 acquisitions at 1 second step continuously (calculated time @25°C. Battery life may be shorter if used in low temperatures) |
Software&Mobile App | SPD, TS Manager |
Accessories | DiskInterface HS, Multibay universale |
Alarms | Local (acoustic and/or visual) on PC (for P-Radio, S-Radio only) |